IF YOU HAVE A POOL THEN DON'T WASTE ANOTHER MINUTE. IT MAKES SENSE TO GO SOLAR FOR THE FOLLOWING REASONS:
LENGTHENS SWIMMING SEASON
If your swimming pool is frequently too cold then you are not getting the most out of your valuable backyard investment.
Depending on where you live, installing a solar heating system can literally double the amount of time you can comfortably use your pool.
MORE ECONOMICAL
When compared to heating your pool with other methods, solar heating pays for itself in less than 3 years.
ADDS VALUE
A solar pool heating system adds value to your pool and home.
ENVIRONMENTALLY SAFE
Solar pool heaters produce clean, positive energy, and do not pollute the environment as many conventional heating sources do.

Our pool panels come in two header sizes and three standard lengths. Once you purchase your system from us we will send you warranty info, a manual and certifications if desired.
The panels are very easy to install and you can do it yourself in 2-3 days. You can either install them on your roof or build a rack. We can also send you a design for building a rack. Just let us know.
If you would rather have professional installation, then we can give you some local recommendations as well.
BASIC Required Products for One Pool System:
1. Panels
2. One collector kit for each panel
3. One system kit for each system
4. One split kit system for each row of panels as well as for extending headers in case there is a vent between panels
5. At least two check valves (one to prevent back wash into your filter, another on the return line to your pool. You may in addition decide to get ball valves for isolation - see manual)
6. One vacuum relief valve normally placed at the highest point above your feed line)
7. Enough strapping for three rows to hold the panels down
8. Automatic control system if you desire an automation or a 3 way valve for manual use.
Click here for more info
ARE YOU READY TO GO SOLAR?
Once you have figured out your sizing and what you need, go on over to the shopping area and start saving by clicking here. You'll feel good when you see your bills and most of all you'll feel good in a nice warm pool. Go Green and enjoy it!
ARE YOU LOOKING FOR REPLACEMENT SOLAR POOL PANELS?
Our panels fit most all other panels out there if you need a replacement. Please check our spec sheet and call us today to place an order for your replacement panels.
TECHNICAL SPECS
| 1.5” Header | 2.0” Header | ||||||
| Size/ Part # |
4 x 12 c15ts12 | 4 x 10 c15ts10 |
4 x 8 c15ts08 |
4 x 12 c20ts12 | 4 x 10 c20ts10 |
4 x 8 c20ts08 |
|
| DIMENSIONS | Units | ||||||
| Overall Length | In | 143.294 | 119.282 | 95.269 | 144.108 | 120.095 | 96.050 |
| Absorber Width | In | 47.638 | 47.638 | 47.638 | 47.638 | 47.638 | 47.638 |
| Header Length | In | 50.75 | 50.75 | 50.75 | 50.75 | 50.75 | 50.75 |
| Header OD | In | 1.9 | 1.9 | 1.9 | 2.31 | 2.31 | 2.31 |
| Header ID | In | 1.48 | 1.48 | 1.48 | 1.89 | 1.89 | 1.89 |
| Gross Area | Sq ft | 50.501 | 42.038 | 33.576 | 50.788 | 42.325 | 33.851 |
| Net Area | Sq ft | 47.404 | 39.460 | 31.517 | 47.673 | 39.730 | 31.775 |
| Number of Flow Channels | 104 | 104 | 104 | 104 | 104 | 104 | |
| Nominal Hole Size | In | .156 | .156 | .156 | .156 | .156 | .156 |
| WEIGHT | |||||||
| Dry | Lbs | 29 | 24 | 19 | 30 | 25 | 20 |
| Wet | Lbs | 62.5 | 53.6 | 44.7 | 64.4 | 55.50 | 46.60 |
| Wet Dispersed | Lbs/sq ft | 1.32 | 1.36 | 1.42 | 1.31 | 1.35 | 1.41 |
| Fluid Capacity | Gal | 4.03 | 3.56 | 3.09 | 4.13 | 3.66 | 3.19 |
| FLOW RATES | |||||||
| Max | Gpm | 10 | 10 | 10 | 10 | 10 | 10 |
| Min | Gpm | 3 | 2.5 | 2.5 | 3 | 2.5 | 2.5 |
| Recommended | Gpm | 4.95 | 4.95 | 4.95 | 4.95 | 4.95 | 4.95 |
| Max # panels in parallel | Panels | 7 | 9 | 11 | 10 | 12 | 14 |
| PRESSURE | |||||||
| Drop | Psi | 0.192 | 0.169 | 0.151 | 0.187 | 0.164 | 0.146 |
| Max test | Psi | 80 | 80 | 80 | 80 | 80 | 80 |
| Max operating range | Psi | +/- 10 | +/- 10 | +/- 10 | +/- 10 | +/- 10 | +/- 10 |
| Max operating spike | Psi | 35 | 35 | 35 | 35 | 35 | 35 |
| PERFORMANCE | |||||||
| FSEC Certification | BTU/day | 45600 | 38100 | 30400 | 45600 | 38100 | 30400 |
| Wind Load | mph | 150 | 150 | 150 | 150 | 150 | 150 |
Disclaimer
*It is your responsibility or the buyer's to make sure to always follow the codes and regulations governing your location in regards to installing our panels yourself or with anyone else qualified or not. Make sure you don't cause leaks on your roof or any other damage to your property or anyone else's and make sure panels are properly secured on your roof or rack per our manual. Make sure our panels are drained when not in use to avoid freeze damage. Neglecting these rules will void warranty. SolarSunPacific.com or its officers or employees are not responsible for any damage caused during installation by you or anyone you hire to help install the panels bought from us. We only provide you with excellent material at a very low and affordable cost to your benefit so take advantage of it now and save by going solar. All claims and warranties must be directly sent to the manufacturer's attention. See our warranty section for more detail.